Digital tachograph. Company card remote authentication error

100 Views Asked by At

I'm trying to perform remote authentication between a tachograph company smart card and an SE5000 tachograph. I'm going through the path partially well, but after the key exchange, when I try to read the binary file, error 6E00 occurs.

Does anyone know what this problem means?

This is the order of commands between the card and the tachograph:

card gives ATR: 3BFC9600008031FE4380718065B0850400FB829000AA

tacho responds: 00A4020C020002

card responds: 9000

tacho responds: 00B0000009

card responds: 00310586EA082304219000

tacho responds: 00A4040C06FF544143484F

card responds: 9000

tacho responds: 0022C1B60A8308001DC0A0062306A2

card responds: 9000

tacho responds: 008800001095F3B213DC034C22001DC0A0062306A280

card responds: 5E8CC0BB5CE5E458E98BA257486EBE18F5653EBE7C6B6DB7517A3ED3814D08F30928B0FEF06E3FD4A8BFD8CA25A408C17D14DE2E3133C2E9076C1F3F90EE1DC8B4A827F2ACE7E452D8D0DE0D6E93A57B770435BB6D85E2ED53196448941A146FF464F23CED35CD61E1B2D878F296B2194646438CB9CFF142174CE64DB83E029C9000

tacho responds: 0084000008

card responds: 7C05CA4A8518DD749000

tacho responds: 00820000805119C3B026D8CC1FF3562E1089AFF5D567584506B7F7A1F723C445D7F9B013F0EB33150DAE197110B31F9F8914E878032295B25640B5E5EF55810C7BC609EEDDDDEDA8E1445BABF2C10D78503813A17071F531604C39444BC7CC880ECFB529247456F00105CAD29006C412D141D1AB950A2B76D6976359D3D218A558D3D10076

card responds: 9000

tacho responds: 00A4020C020520

card responds: 9000

tacho responds: 0CB000000997018B8E04B991986F

card responds: 6E00 //Class not supported

I made a request through the supplier to the tachograph manufacturer. But so far there is no answer.

Stoneridge It was said here that Stoneridge tachographs may require additional adjustments in the workshop. Does anyone know what needs to be configured?

0

There are 0 best solutions below